STER PMU Quick Start Manual Introduction 6 1.2 SAFETY CONSIDERATIONS To ensure operator safety while using the STER PMU instruments and to mini

Strany 3

STER PMU Quick Start Manual Description 7 2 Description 2.1 FRONT PANEL 1234567 Figure 2.1: Front panel Front panel layout: 1 LCD Graphic d

Strany 4

STER PMU Quick Start Manual Description 8 2.2 CONNECTOR PANEL IN I3 C B A I1 L1 L3C N A I2 L2 B 12 Warning! Use safety test leads only! Max

Strany 5 - Document Revisions Record

STER PMU Quick Start Manual Description 9 2.3 BOTTOM VIEW MI 2792CAT III 1000VIP40 Figure 2.4: Bottom view Bottom view layout: 1 Battery compa

Strany 6

STER PMU Quick Start Manual Description 10 Voltage measurement cable, black 1 Voltage measurement cable, green 1 USB to female DB9 cable 1 Male

Strany 7

STER PMU Quick Start Manual Getting started 11 3 Getting started 3.1 CONFIGURING THE SERIAL TO ETHERNET CONVERTER If GPRS modem is used for re

Strany 8

STER PMU Quick Start Manual Getting started 12 SENA PS110AC/DC adaptor Figure 3.1: Powering on the PS110 modem To reset all settings to their de

Strany 9 - 1 Introduction

STER PMU Quick Start Manual Getting started 13 Figure 3.4: HyperTerminal serial connection settings dialog 6. Open the connection. 7. Direct

Strany 10 - 1.3 APPLICABLE STANDARDS

STER PMU Quick Start Manual Getting started 14 Enter Network configuration menu from the main menu by typing 1 and pressing Enter. Then, enter t

Strany 11 - 2 Description

STER PMU Quick Start Manual Getting started 15 Figure 3.10: Serial port configuration overview In the serial port configuration overview select

Strany 13 - 2.4.1 STANDARD ACCESSORIES

STER PMU Quick Start Manual Getting started 16 Figure 3.12: Serial port parameters 12. Save and apply changes by entering the save command, fo

Strany 14 - 2.4.2 OPTIONAL ACCESSORIES

STER PMU Quick Start Manual Getting started 17 3.2 CABLING AND CONNECTING THE DEVICE 3.2.1 CONNECTING THE POWER SUPPLY AND POWERING ON STER PM

Strany 15 - 3 Getting started

STER PMU Quick Start Manual Getting started 18 It is presumed that configuration of the modem has been completed before continuing with this ch

Strany 16 - RS-232 mode

STER PMU Quick Start Manual Getting started 19 3.3 CONFIGURING THE DEVICE FOR FIRST USE 3.3.1 MAIN SCREEN After powering on, main device scree

Strany 17

STER PMU Quick Start Manual Getting started 20 Figure 3.18: Accessing the SETUP menu There are 3 setup menu items in the SETUP menu:  MEASUR

Strany 18

STER PMU Quick Start Manual Getting started 21 For detailed help on using the online web interface, please consult Chapter 6: Using the Wamster

Strany 19

STER PMU Quick Start Manual Working with the instrument 22 4 Working with the instrument 4.1 CHANGING MEASUREMENT SETTINGS In most cases, it i

Strany 20 - INTERFACE

STER PMU Quick Start Manual Working with the instrument 23 Table 4.3: 4W measurement ranges Range name Peak (V) Meas. type VT connection Power

Strany 21 - 110VAC/12VDC

STER PMU Quick Start Manual Working with the instrument 24 Using the up ( ) and down ( ) keys select the Current range menu item, and then use l

Strany 22

STER PMU Quick Start Manual Working with the instrument 25 4.4.2 CONNECTING CURRENT TERMINALS IN I3 C B A I1 L1 L3C N A I2 L2 B IN,I3,I2,I1

Strany 23 - 3.3.2 SETUP MENU

STER PMU Quick Start Manual rev. 1.0.982 Studio Elektronike Rijeka d.o.o.  HR-51000 Rijeka, Croatia Tel:

Strany 24

STER PMU Quick Start Manual Working with the instrument 26 IN I3 C B A I1 L1 L3C N A I2 L2 B Figure 4.11: Wiring configuration for a 3-p

Strany 25 - 3.3.5 POWERING OFF

STER PMU Quick Start Manual Working with the instrument 27 IN I3 C B A I1 L1 L3C N A I2 L2 B Figure 4.13: Wiring configuration for a 3-p

Strany 26 - 4.2 VOLTAGE MEASUREMENT

STER PMU Quick Start Manual Working with the instrument 28 4.6 SYNCHRONIZATION Synchronization input channel is used as a frequency measurement

Strany 27 - 4.3 CURRENT MEASUREMENT

STER PMU Quick Start Manual Instrument maintenance 29 5 Instrument maintenance 5.1 CHANGING BATTERIES STER PMU uses six rechargeable NiMh batt

Strany 28

STER PMU Quick Start Manual Instrument maintenance 30 5.3 BATTERIES Instrument contains rechargeable NiMh batteries. These batteries should onl

Strany 29 - 4-WIRE (4W) 3-PHASE SYSTEM

STER PMU Quick Start Manual Instrument maintenance 31 5.6 PERIODIC CALIBRATION To ensure correct measurement, it is essential that the instrume

Strany 30 - 3-WIRE (3W) 3-PHASE SYSTEM

STER PMU Quick Start Manual Using the Wamster web interface 32 6 Using the Wamster web interface After the device has connected to the server,

Strany 31

STER PMU Quick Start Manual Using the Wamster web interface 33 21 Figure 6.2: User area: 1. navigation menu, 2. login status with a Logout lin

Strany 32 - 4.7 FREQUENCY

STER PMU Quick Start Manual Using the Wamster web interface 34 123 Figure 6.4: Visual status indicators and command buttons Visual status indic

Strany 33 - 5 Instrument maintenance

STER PMU Quick Start Manual Using the Wamster web interface 35 6.4 DEVICE COMPARATION To compare measurements of your devices, use the Compare

Strany 35 - 5.8 TROUBLESHOOTING

STER PMU Quick Start Manual Using the Wamster web interface 36 6.4.2 SWITCHING BETWEEN REAL-TIME AND HISTORICAL VIEWS By default, Compare page

Strany 36 - 6.2 SIGNING IN TO WAMSTER

STER PMU Quick Start Manual Using the Wamster web interface 37 On the left side of the page, there is panel for creating new export requests, wh

Strany 37 - 6.3 OVERVIEW

STER PMU Quick Start Manual Using the Wamster web interface 38 Figure 6.11: If the remote instrument is in a different menu than the one shown

Strany 38

Document Revisions Record Revision DESCRIPTION OF CHANGE APPROVED BY DATE APPROVED 1.0.885 Initial publication DB 2011-10-31 1.0.982 Updated wit

Strany 40

STER PMU Quick Start Manual Table of Contents 3 1 Introduction ...

Strany 41 - 6.6 REMOTE ACCESS

STER PMU Quick Start Manual Table of Contents 4 5 Instrument maintenance ......

Strany 42 - 6.7 SUPPORT PAGE

STER PMU Quick Start Manual Introduction 5 1 Introduction STER PMU is a handheld synchrophasor measurement unit, equipped with a rechargea